Coupled Coplanar Lines

C_NCOUP (N=1,2,3,...,10) represents N multiple coupled coplanar lines. The geometrical dimensions of the coupled lines are defined using the data item addressed by C_NL_TYP. L is the length of the coupled section. The substrate data are defined in data item addressed by C_SUB.

Parameters  

Parameter Description
L  Line length (stretchable)
C_NL_TYP IID of data items with the geometrical dimensions of coupled coplanar lines
C_SUB ID of coplanar substrate definition
C_GRID ID of simulation control data
TEMP ID of element temperature definition used for noise computation

Notes

Equivalent Circuit  

See Analysis of Multiple Coupled Coplanar Lines